Description
These replacement parts fit the Matala VersiFlow Pump series. How to know which parts to replace:
- If your direct drive pump breaks the GFI on our outdoor receptacle but does not make noise and runs when plugged into a non-GFI outlet, you probably need a rebuild kit. Fresh oil, gaskets, and O-rings may fix your pump. This is true in most cases.
- If your direct drive pump whirs or hesitates but will start when you help start the impeller spinning manually, your pump probably needs a capacitor.
- If your direct drive pump makes a grinding sound, it probably needs new bearings.
- If the shaft on your direct drive pump is frozen and doesn't turn at all, you probably need a new pump.